BZNDQ - KODAK SPEED CHECK RA DEVELOPER REPLENISHER, WORKING SOLUTION

  • MSDS: BZNDQ
  • Manufacturer: EASTMAN KODAK COMPANY
  • Product Name: KODAK SPEED CHECK RA DEVELOPER REPLENISHER, WORKING SOLUTION
  • National Stock Number: 6750-00D004955
Product Identification

Product ID:KODAK SPEED CHECK RA DEVELOPER REPLENISHER, WORKING SOLUTION
MSDS Date:05/30/1995
FSC:6750
NIIN:00D004955
Kit Part:Y
MSDS Number: BZNDQ

Responsible Party
EASTMAN KODAK COMPANY
343 STATE STREET
ROCHESTER, NY 14650
US

Emergency Phone: 716-722-5151

Info Phone: 800- 242-2424

Cage: 19139

Contractor
EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
ROCHESTER, NY 14650-1115 US

Telephone: 716-722-5151/(800) 242-2424

Cage: 19139

Ingredients

POTASSIUM CARBONATE

CAS: 584-08-7

RTECS: TS7750000

Fraction By Weight: 1-5%


ETHANOL, 2,2',2"-NITRILOTRI-; (TRIETHANOLAMINE)

CAS: 102-71-6

RTECS: KL9275000

Fraction By Weight: 1-5%

ACGIH TLV: 5 MG/M3


DIETHYLHYDROXYLAMINE

CAS: 25646-71-3

RTECS: PB0431000

Fraction By Weight: <1%


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 95-100%

Hazards

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION: EXPECTED TO BE LOW HAZARD
FOR RECOMMENDED HANDLING. EYES: NO SPECIFIC HAZARD KNOWN. MAY CAUSE
TRANSIENT IRRITATION. SKIN: MAY CAUSE IRRITATION. MAY CAUSE
ALLERGIC SKIN REACTION. INGESTION: HARMFUL IF SWALLOWED. MAY CAUSE
IRRITATION OF THE GASTROINTESTINAL TRACT.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION-MOVE TO FRESH AIR. TREAT SYMPTOMATICALLY. GET
MEDICAL ATTENTION IF SYMPTOMS PERSIST. EYES-IMMEDIATELY FLUSH WITH
PLENTY OF WATER FOR 15 MIN. GET MEDICAL ATTENTION IF SYMPTOMS
OCCUR. SKIN-IM MEDIATELY REMOVE SOILED CLOTHES/SHOES &WASH WITH
SOAP & WATER. GET MEDICAL ATTENTION IF SYMPTOMS OCCUR.
INGESTED-DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL ATTENTION.

Fire Fighting

Flash Point:NONE
Extinguishing Media:USE APPROPIATE GANET FOR ADJACENT FIR.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:ELIMINATE ALL IGNITION SOURCES. MAY REQUIRE
NEUTRALIZATION IF PH <2 OR >12.5. FLUSH TO SEWER WITH LARGE AMOUNTS
OF WATER. OTHERWISE, ABSORB SPILL WITH VERMICULITE OR OTHER INERT
MATERIAL, THEN PLACE I N A CONTAINER FOR CHEMICAL WASTE.
CLEANSURFACE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:KEEP CONTAINER CLOSED.
Other Precautions:USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING.

Exposure Controls

Respiratory Protection:NONE SHOULD BE NEEDED.
Ventilation:GOOD GENERAL VENTILATION (TYPICALLY 10 AIR CHANGES/HR)
SHOULD BE USED. VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS
Protective Gloves:WEAR IMPERVIOUS GLOVES FOR THE RISK.
Eye Protection:WEAR SAFETY GLASSES WITH SIDE SHIELD.
Other Protective Equipment:EYE BATH, SAFETY SHOWER, WASHING FACILITIES.
Work Hygienic Practices:GOOD INDUSTRIAL HYGIENE PRACTICES TO MINIMIZE
SKIN CONTACT AND INHALATION.
Supplemental Safety and Health
NONE

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:>212F,>100C
Vapor Pres:18 MMHG
Vapor Density:0.6
Spec Gravity:1.03
pH:10.8
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, YELLOW, SLIGHT AMINE ODOR.
Percent Volatiles by Volume:90-95

Stability

Stability Indicator/Materials to Avoid:YES
NONE WITH COMMON MATERIALS AND CONTAMINANTS WITH WHICH THE MATERIAL MAY
REASONABLY COME INTO CONTACT.
Stability Condition to Avoid:STABLE.
Hazardous Decomposition Products:NONE.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISCHARGE, TREATMENT, OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE, OR LOCAL LAWS. FLUSH TO SEWER WITH LARGE
AMOUNTS OF WATER.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.